Solar hot water systems capable of complying with the 5 Star regulation:
Continuous electric solar systems recommended for households with 1-2 bedrooms
 
 
Manufacturer
System Type Model Number Solar Savings Tank
Size
Litres
Tank Model
Number
Collector
Type
Collector
Model
Number
Number of
Collectors/Tubes
Frost
Protection
AAE Solar Pumped in-tank boost AAE-270-GLES-30 72 % 269 250GLES Evacuated Tube SCM-20 30 Recirculation pump & glasswool insulation
Aquamax Pumped in-tank boost SE424-036-107-01 65 % 261 SE424 Flat plate 07 1 Hitachi Frost Protection valve and Aquamax differential controller
AquaMax Pumped in-tank boost SE424-036-204-02 69 % 261 SE424 Flat Plate 04 2 Hitachi Frost Protection valve and Aquamax differential controller
AquaMax Pumped in-tank boost SE424-036-207-02 79 % 261 SE424 Flat Plate 07 2 Hitachi Frost Protection valve and Aquamax differential controller
Aquamax Pumped in-tank boost SE425-036-107-01 65 % 315 SE425 Flat plate 07 1 Hitachi Frost Protection valve and Aquamax differential controller
AquaMax Pumped in-tank boost SE425-036-204-02 70 % 325 SE425 Flat Plate 04 2 Hitachi Frost Protection valve and Aquamax differential controller
AquaMax Pumped in-tank boost SE425-036-207-02 81 % 325 SE425 Flat Plate 07 2 Hitachi Frost Protection valve and Aquamax differential controller
Aquamax Pumped in-tank boost SE426-036-107-01 62 % 417 SE426 Flat plate 07 1 Hitachi Frost Protection valve and Aquamax differential controller
AquaMax Pumped in-tank boost SE426-036-207-02 79 % 417 SE426 Flat Plate 07 2 Hitachi Frost Protection valve and Aquamax differential controller
Chromagen Close-coupled thermosyphon with in-tank boost 8301TCBC12 64 % 300 EH300NM2E01 Flat Plate CR120BC 1 Anti-Freeze Close loop System
Chromagen Close-coupled thermosyphon with in-tank boost 8301TOBC12 70 % 300 SH30ANR2G01 Flat Plate CR120BC 1 Anti-Frost Valve
Chromagen Pumped in-tank boost 8301VCBC12 60 % 300 EV30ANS0G09 Flat Plate CR120BC 1 Anti-Freeze Close loop System
Chromagen Pumped in-tank boost 8301VOBC12 70 % 300 SV30ANR1G09 Flat Plate CR120BC 1 Active Control in Solar Controller
Chromagen Close-coupled thermosyphon with in-tank boost 8302TCBP10 74 % 300 EH300NM2E01 Flat Plate CR100BP 2 Anti-Freeze Close loop System
Greenland Systems Pumped in-tank boost EGL10016-260 - C 72 % 260 250 S Evacuated Tube GL100-16 1 Frost Protection Valve
Greenland Systems Pumped in-tank boost EGL10016-320 - C 71 % 320 315 S Evacuated Tube GL100-16 1 Frost Protection Valve
Greenland Systems Pumped in-tank boost EGL10016PT-260 - C 69 % 260 250 S Evacuated Tube GL100-16PT 1 Frost Protection Valve
Greenland Systems Pumped in-tank boost EGL10016PT-320 - C 68 % 320 315 S Evacuated Tube GL100-16PT 1 Frost Protection Valve
Greenland Systems Pumped in-tank boost EGL7020-260 - C 65 % 260 250 S Evacuated Tube GL70-20 1 Frost Protection Valve
Rinnai Sunmaster Pumped in-tank boost SE2003P 73 % 200 SE200 Flat Plate SP200 3 None
Sunplus Solar Pumped in-line boost CPCBME1 72 % 250 250M Evacuated tube CPC6 3 Recirculation
Sunplus Solar Pumped in-line boost CPCBME4 74 % 315 315M Evacuated tube CPC6 3 Recirculation