| AAE Solar |
Pumped in-tank boost |
AAE-270-GLES-30 |
72 % |
269 |
250GLES |
Evacuated Tube |
SCM-20 |
30 |
Recirculation pump & glasswool insulation |
| Aquamax |
Pumped in-tank boost |
SE424-036-107-01 |
65 % |
261 |
SE424 |
Flat plate |
07 |
1 |
Hitachi Frost Protection valve and Aquamax differential controller |
| AquaMax |
Pumped in-tank boost |
SE424-036-204-02 |
69 % |
261 |
SE424 |
Flat Plate |
04 |
2 |
Hitachi Frost Protection valve and Aquamax differential controller |
| AquaMax |
Pumped in-tank boost |
SE424-036-207-02 |
79 % |
261 |
SE424 |
Flat Plate |
07 |
2 |
Hitachi Frost Protection valve and Aquamax differential controller |
| Aquamax |
Pumped in-tank boost |
SE425-036-107-01 |
65 % |
315 |
SE425 |
Flat plate |
07 |
1 |
Hitachi Frost Protection valve and Aquamax differential controller |
| AquaMax |
Pumped in-tank boost |
SE425-036-204-02 |
70 % |
325 |
SE425 |
Flat Plate |
04 |
2 |
Hitachi Frost Protection valve and Aquamax differential controller |
| AquaMax |
Pumped in-tank boost |
SE425-036-207-02 |
81 % |
325 |
SE425 |
Flat Plate |
07 |
2 |
Hitachi Frost Protection valve and Aquamax differential controller |
| Aquamax |
Pumped in-tank boost |
SE426-036-107-01 |
62 % |
417 |
SE426 |
Flat plate |
07 |
1 |
Hitachi Frost Protection valve and Aquamax differential controller |
| AquaMax |
Pumped in-tank boost |
SE426-036-207-02 |
79 % |
417 |
SE426 |
Flat Plate |
07 |
2 |
Hitachi Frost Protection valve and Aquamax differential controller |
| Chromagen |
Close-coupled thermosyphon with in-tank boost |
8301TCBC12 |
64 % |
300 |
EH300NM2E01 |
Flat Plate |
CR120BC |
1 |
Anti-Freeze Close loop System |
| Chromagen |
Close-coupled thermosyphon with in-tank boost |
8301TOBC12 |
70 % |
300 |
SH30ANR2G01 |
Flat Plate |
CR120BC |
1 |
Anti-Frost Valve |
| Chromagen |
Pumped in-tank boost |
8301VCBC12 |
60 % |
300 |
EV30ANS0G09 |
Flat Plate |
CR120BC |
1 |
Anti-Freeze Close loop System |
| Chromagen |
Pumped in-tank boost |
8301VOBC12 |
70 % |
300 |
SV30ANR1G09 |
Flat Plate |
CR120BC |
1 |
Active Control in Solar Controller |
| Chromagen |
Close-coupled thermosyphon with in-tank boost |
8302TCBP10 |
74 % |
300 |
EH300NM2E01 |
Flat Plate |
CR100BP |
2 |
Anti-Freeze Close loop System |
| Greenland Systems |
Pumped in-tank boost |
EGL10016-260 - C |
72 % |
260 |
250 S |
Evacuated Tube |
GL100-16 |
1 |
Frost Protection Valve |
| Greenland Systems |
Pumped in-tank boost |
EGL10016-320 - C |
71 % |
320 |
315 S |
Evacuated Tube |
GL100-16 |
1 |
Frost Protection Valve |
| Greenland Systems |
Pumped in-tank boost |
EGL10016PT-260 - C |
69 % |
260 |
250 S |
Evacuated Tube |
GL100-16PT |
1 |
Frost Protection Valve |
| Greenland Systems |
Pumped in-tank boost |
EGL10016PT-320 - C |
68 % |
320 |
315 S |
Evacuated Tube |
GL100-16PT |
1 |
Frost Protection Valve |
| Greenland Systems |
Pumped in-tank boost |
EGL7020-260 - C |
65 % |
260 |
250 S |
Evacuated Tube |
GL70-20 |
1 |
Frost Protection Valve |
| Rinnai Sunmaster |
Pumped in-tank boost |
SE2003P |
73 % |
200 |
SE200 |
Flat Plate |
SP200 |
3 |
None |
| Sunplus Solar |
Pumped in-line boost |
CPCBME1 |
72 % |
250 |
250M |
Evacuated tube |
CPC6 |
3 |
Recirculation |
| Sunplus Solar |
Pumped in-line boost |
CPCBME4 |
74 % |
315 |
315M |
Evacuated tube |
CPC6 |
3 |
Recirculation |